Self-Testing Your Products

Learn how to properly label and complete the self-testing drop sequence for non-fragile and non-liquid ASINs in rigid packaging.
Learn how to properly label and complete the self-testing drop sequence for non-fragile and non-liquid flexible packaged ASINs.
Drop testing
Mark 45.7cm and 91.4cm on a table leg or wall. Drop the box/mailer from the height onto the face, edge, or corner in the order listed below.
Drop | Orientation | Height | |
1 | Edge | 3-4 | 45.7cm |
2 | Edge | 3-6 | 45.7cm |
3 | Edge | 4-6 | 45.7cm |
4 | Corner | 3-4-6 | 45.7cm |
5 | Corner | 2-3-5 | 45.7cm |
6 | Edge | 2-3 | 45.7cm |
7 | Edge | 1-2 | 45.7cm |
8 | Face | 3 | 91.4cm |
9 | Face | 3 | 45.7cm |
10 | Edge | 3-4 | 45.7cm |
11 | Edge | 3-6 | 45.7cm |
12 | Edge | 1-5 | 45.7cm |
13 | Corner | 3-4-6 | 45.7cm |
14 | Corner | 1-2-6 | 45.7cm |
15 | Corner | 1-4-5 | 45.7cm |
16 | Face | Most fragile | 91.4cm |
17 | Face | 3 | 45.7cm |